Five common problems about bottle blowing machine and their solutions

Update:23-05-2020
Summary:

1, the feeding position is not feeding Several situatio […]

1, the feeding position is not feeding

Several situations need to be checked:

Whether the hopper is out of stock. If it is, you need to quickly feed; if not, please check whether the control contactor of the hoist is in the state of power. If it is in the power-on state, quickly check whether the motor is in the power-on and load state, because this situation is probably caused by the preform (preform) jamming the lifting belt. At this time, the easiest way is to manually help the lifting. If it is checked that the control contactor of the hoist is not energized, please check whether the preform detection eye is not on the same straight line as the reflector.

2. Feed the old card feed tray

This situation is a headache problem. From an empirical point of view, if the length of the preform (preform) is relatively long and the weight is large, then this phenomenon is relatively small.

3. The bottle cannot be taken out of the mold after blowing

First of all, the mold should be opened, and the mold should be opened and closed manually. If it is normal, run it in the dry running state, if it is normal. Please check your exhaust time setting. If the exhaust setting is normal and every time a bottle blows, it can be judged to be a problem with the exhaust valve. Please open the exhaust valve to check the condition of its spring and seal (this This kind of fault and another phenomenon is that the exhaust sound is relatively loud or there is a dirty sound). If you encounter a situation where many molds are produced normally and accidentally come to such a situation that the mold cannot be opened, please check whether the clamping pin has a segment of the screw in it, and also check whether the clamping force is too strong, if it is too large, you should follow Standard readjustment.

4, the bottle is always pinched

Whether the position of the manipulator is misaligned.

5. Two robots collide

In this case, it is necessary to manually reset the manipulator again, which is caused by misalignment.